Defender 510 / 520

Dry Gas Flow Calibrator

Product Name: Dry Gas Flow Calibrator

Model:Defender 510 / 520

 

The new generation of dry gas flow meters is a primary flow meter recommended and used in conjunction with numerous individual sampling pump manufacturers. It can be used in the fields of industrial hygiene, environmental protection, and various laboratories. It adopts the principle of dry piston movement, and can generate multiple consecutive readings with one press of a button. Compared with the traditional foam flowmeter, it is more convenient and fast to use. The 520 model has added the function of simultaneously testing temperature and pressure compared to the 510 model.

Functional characteristics

  • Compact
 
  • Wide display screen
  • Adopting dry piston principle, easy and convenient to use
 
  • Up to 100 readings per group
  • Accurate flow control, certified to ISO 17025
 
  • Can be equipped with built-in temperature and pressure sensors to optimize test results (520 series)

Technical specifications

Main indicators
Flow range

Defender 510:

510 L,5 ~ 500 ml/min

510 M,50 ~5000 ml/min

510 H,300 ~ 30000 ml/min

 

Defender 520:

520 L,5 ~ 500 ml/min

520 M,50 ~5000 ml/min

520 H,300 ~ 30000 ml/min

Flow accuracy1 %
Standard accuracyN / A
Optional measurement unit - flow ratemL / min,L / min,cc / min,cf / min
Optional measurement units - standardizationN / A
Optional measurement units - temperature

Defender 510:N / A

Defender 520:℃  ℉

Optional measurement units - pressure

Defender 510:N / A

Defender 520:mmHg,PSI,kPa

Temperature and pressure sensors

Defender 510:No

Defender 520:Yes

Pressure

Defender 510:N / A

Defender 520:3.5 mmHg(Typical)、7.0 mm(Max)

Temperature

Defender 510:N / A

Defender 520:0.8 ℃(Typical)、1.3 ℃(Max)

Time of each reading1 ~ 15 s
Reading modesSingle (manual), continuous or burst mode
Gas compatibilityNon corrosive gas, non condensing gas, humidity less than 70%
Flow patternCompression or suction
Measurement unitIntegrated
AC AC/DC Transformer/Charger12 V DC,>250 ma,2.5 mm Center position
Type

6 V rechargeable sealed lead-acid battery,

Typical working hours 6-8 hours

Battery running time (5 times/minute)Turn on the backlight for 3 hours and turn off the backlight for 8 hours
Pressing or suction accessoriesHose
Operating pressure (absolute)15 PSI
DisplayGraphic LCD LCD display with backlight
Data port (using optimization software)RS - 232 Serial port
Data cable (using optimization software)1 meter calibrator to computer serial port
Protection boxSoft or hard instrument box
Size(H × W × D)140 × 150 × 75 mm
Weight820 g